汕头市附近的按摩会所-汕头市附近的按摩会所_第1页

在常州酒店晚上怎么叫服务

Current location: home page > Product Center > Gas phase liquid nitrogen tank >/ bander bender gas phase liquid nitrogen tank

contact us
CONTACT US

Telephone :010-80204245
mobile phone :15611258074
Q Q : 2678388834
mailbox :2678388834@qq.com
address : Anshun South Road, Huangcun, Daxing District, Beijing
 Gas phase liquid nitrogen tank

Bander bender gas phase liquid nitrogen tank

Type number YDD-1000
Parameters
model YDD-1000
Tank parameters
Liquid nitrogen quantity at the bottom of tray (L) one hundred and thirty-five
Volume of sample storage space (L) eight hundred and eight
Geometric volume of tank (L) one thousand and seventy-two
Effective volume of tank (L) one thousand and fourteen
Tank diameter (mm) four hundred and sixty-five
Internal effective height (mm) nine hundred
Tank outer diameter (mm) one thousand one hundred and ninety
Total tank height (mm) one thousand seven hundred and four
Empty weight of tank (kg) four hundred and ninety-five
  Band bender Gas phase liquid nitrogen tank YDD-1000

Band bender Gas phase liquid nitrogen tank It is designed and manufactured according to GB 14174-2012 large diameter liquid nitrogen container. This product is specially developed for large capacity storage of stem cells, embryos and sperm, as well as the Preservation Center. The product is equipped with intelligent differential pressure liquid level meter to monitor the liquid level of liquid nitrogen, with liquid level limit alarm function, safe and reliable use. Users can also use the monitoring function of the liquid level meter to control the automatic replenishment system. This product adopts advanced high vacuum multi-layer insulation technology and advanced insulation structure. While providing large-diameter operation interface, it can still maintain a low daily evaporation rate of liquid nitrogen, and has the characteristics of large storage capacity of biological products, low loss of liquid nitrogen, convenient operation, beautiful appearance and long service life. The liquid nitrogen container (the third generation) of Bande series biological sample bank is a national patent product (Patent No.: zl20072008194b. X) developed on the basis of absorbing excellent products at home and abroad, Vigorously Innovating and actively promoting. Biological sample bank liquid nitrogen tank
Ydd-1000 type Bander bender gas phase liquid nitrogen tank The effective volume is 1014 L, the daily evaporation rate of liquid nitrogen is only 0.82l, and the maximum storage capacity is 49500 2ml inner rotating cryopreservation tubes. It is an important equipment for large capacity storage of biological samples and blood products. The maximum storage capacity of 25ml blood bag was 4320.

 Gas phase liquid nitrogen tank

model YDD-1000
Tank parameters
Liquid nitrogen quantity at the bottom of tray (L) one hundred and thirty-five
Volume of sample storage space (L) eight hundred and eight
Geometric volume of tank (L) one thousand and seventy-two
Effective volume of tank (L) one thousand and fourteen
Tank diameter (mm) four hundred and sixty-five
Internal effective height (mm) nine hundred
Tank outer diameter (mm) one thousand one hundred and ninety
Total tank height (mm) one thousand seven hundred and four
Empty weight of tank (kg) four hundred and ninety-five
Tank operation height nine hundred and fifty
Full load total weight (kg) 1314 
Door width requirement ≥ mm one thousand two hundred and ten
Daily evaporation rate% zero point eight two
supply voltage 220VAC、24VDC
Maximum storage quantity of 0.5ml frozen tube
Quantity of 0.5ml standard frozen tube sixty-six thousand
Quantity of 5 × 5 0.5ml bucket four
Quantity of 10 × 10 0.5ml bucket thirty-two
Quantity of 5 × 5 boxes eighty
10 × 10 box quantity six hundred and forty
Layers of 0.5ml bucket twenty
Size of 5 × 5 0.5ml frozen box 76*76*40
Size of 10 × 10 0.5ml frozen box 134*134*40
Size of 5 × 5 0.5ml freezer 82*84*42
Size of 10 × 10 0.5ml freezer 142*144*42
Maximum storage quantity of 2ml inner rotating frozen tube
Quantity of 1.2,1.8,2ml inner rotating frozen tubes forty-nine thousand and five hundred
Quantity of 5 × 5M3 pail thirty-two
Quantity of 10 × 10 m3 bucket four
Quantity of 5 × 5 boxes sixty
10 × 10 box quantity four hundred and eighty
Layers of square bucket fifteen
Size of 5 × 5.2ml frozen box 76*76*54
Size of 10 × 10 2ml frozen box 134*134*54
Size of 5 × 5.2ml freezer 82*84*56
Size of 10 × 10 2ml freezer 142*144*56
Maximum storage quantity of 2ml sample frozen box
Quantity of 2ml external rotating frozen tube twenty-one thousand and fifty-six
Quantity of sample freezing rack one hundred and eighty-eight
Number of sample frozen boxes two thousand six hundred and thirty-two
Layer number of sample frozen shelf fourteen
Frozen box size 161*58*18
Frozen shelf size 163*62*23
Maximum storage quantity of 5ml dwarf frozen storage tube
Quantity of 5ml frozen storage tube (dwarf type) fourteen thousand two hundred and fifty-six
Quantity of 3 × 3.5ml bucket four
Quantity of 6 × 6.5ml square pail thirty-two
Quantity of 3 × 3 frozen boxes forty-eight
Quantity of 6 × 6 frozen boxes three hundred and eighty-four
Layers of 5ml bucket twelve
Size of 3 × 3.5ml frozen box 76*76*67
Size of 6 × 6.5ml frozen box 134*134*67
Size of 3 × 3.5ml freezer 82*84*70
Size of 6 × 6.5ml freezer 142*144*70
Maximum storage quantity of 5ml slender frozen tube
Quantity of 5ml frozen storage tube (slender type) twenty-one thousand five hundred and thirty-six
Quantity of 5 × 5.5mL bucket four
Quantity of 9 × 9 5ml bucket thirty-two
Quantity of 5 × 5 frozen boxes thirty-two
Quantity of 9 × 9 frozen boxes two hundred and fifty-six
Layers of 5ml bucket eight
Size of 5 × 5.5mL frozen box 76*76*100
Size of 9 × 9.5ml frozen box 134*134*100
Size of 5 × 5.5mL freezer 82*84*102
Size of 9 × 9.5ml freezer 142*144*102
Maximum storage quantity of straw
Quantity of 0.5ml fine tube (wheat tube) three hundred and sixty-five thousand nine hundred and four
Quantity of 0.25ml fine tube (straw) eight hundred and thirty-nine thousand two hundred and thirty-two
Number of round lifting cylinders one hundred and twenty
Number of round lifting cylinders sixteen
Number of round lifting cylinders forty
Layers of round lifting cylinder six
Floor height one hundred and thirty-five
Maximum storage quantity of blood bags
Blood bag specification Total bags Number of layers Number of blood bags
25ml(791 OS/U) four thousand three hundred and twenty nine four hundred and eighty
50ml(4R9951) two thousand five hundred and ninety-two nine two hundred and ninety-six
200ml(DF-200) two thousand five hundred and ninety-three five one hundred and thirty-six
250ml(4R9953) one thousand one hundred and eighty five two hundred and thirty-six
500ml(4R9955) eight hundred five one hundred and sixty
700ml(DF-700) four hundred five eighty

Technical characteristics of gas phase liquid nitrogen tank:

(1) the gas-phase liquid nitrogen tank can be compatible with gas-phase and liquid-phase storage modes;
A variety of capacities are available to meet your storage needs to the maximum extent;
(3) more samples are stored in the unit area, and the storage cost is reduced by the gas-phase liquid nitrogen tank;
Excellent temperature uniformity and stability;
(5) excellent temperature stability after cover opening;
The advanced liquid nitrogen level and temperature monitoring system can be connected with each other;
Automatic supply of liquid nitrogen system, safe and labor-saving;
The micro processing control system of gas phase liquid nitrogen tank can save the operation data permanently;
(9) one key defogging function, convenient to find and place samples;
Many humanized design, comfortable operation;
⑪ the tank cover can be locked, and the gas-phase liquid nitrogen tank can fully ensure the sample safety;
⑫ integrated folding steps and auxiliary worktable are provided as standard;
⑬ the products meet CE quality certification;


Technical characteristics of liquid nitrogen tank

A biological sample bank of ultra-low temperature gas-phase liquid nitrogen tank has the function of automatic measurement and control. The liquid is supplied by low-temperature pipeline in a centralized way, which reduces the labor intensity of operation and improves the reliability of biological samples. The state of liquid nitrogen container is monitored by remote monitoring system, and sent out by monitoring room
The gas-phase liquid nitrogen tank has the functions of data storage, printing and wireless alarm. The low oxygen alarm system is installed in the liquid nitrogen freezer, which can automatically exhaust and extract air, so as to prevent the danger of suffocation caused by excessive oxygen concentration in the operation environment. Liquid nitrogen gas tank
It is suitable for large animal husbandry frozen semen station, hospital blood bank, stem cell storage center, biological sample storage center of Scientific Research Institute, etc.





The structural features of the gas phase liquid nitrogen tank are as follows

1. The shell and the inner liner are composed of the upper and lower heads and the middle straight cylinder, which are all made of high-quality stainless steel. Strict process means and advanced welding equipment for gas-phase liquid nitrogen tank are used in the production to ensure the reliability of welding and appearance quality. Gas phase liquid
The specially designed connection support structure with low heat conduction is adopted for the connection between the inner tank and the outer shell of the nitrogen tank, which reduces the solid heat transfer under the premise of ensuring high strength.

2. The rotating tray in the liquid nitrogen tank has a good structure to ensure easy and convenient rotation. Pallets are divided into 6 equal parts according to the number of external lifting cylinders. The six areas of the tray are numbered in sequence. The liquid nitrogen tank can be seen on the rotating handle of the tray,
It is convenient for users to identify and distinguish frozen articles without confusion.

3. The liquid inlet valve group adopts double solenoid valve structure design, and the leakage probability of the solenoid valve is further reduced. The valve group is equipped with a heat discharge solenoid valve to avoid hot gas entering the tank body when adding liquid. The gas phase liquid nitrogen tank ensures the sample safety to the greatest extent.

The liquid nitrogen layer with the highest heat conductivity and the lowest gas permeability is obtained by using the multi-layer insulation technology.

5. The advanced vacuum technology is adopted for the vacuum interlayer of the gas-phase liquid nitrogen tank. The excellent high vacuum can be obtained, the outgassing rate is extremely low, and the service life of the product is not less than 5 years.

6. The vacuum interlayer of the gas-phase liquid nitrogen tank is filled with adsorbent which has been treated by special activation process and has good adsorption performance at low temperature, which can ensure a higher vacuum degree in the service life of the product.




Usage of gas phase liquid nitrogen tank


1. The amount of liquid nitrogen to be filled in the gas-phase liquid nitrogen tank for the first time should not exceed the tray. After the tank is completely cold through, add the liquid nitrogen to the set height, and then stand for 24 hours after the completion of liquid supplement. After the tank temperature is uniform, the storage sample can be put into storage.

2. Because of the large diameter of the container, the cold air at the mouth of the container will contact with the outside air when the cover is opened, which will cause the water vapor in the air to condense into fog, which will hinder the sight line. When the air humidity is high, it is especially serious, and even can not see the inside of the container completely, so it is necessary for normal operation
Gas phase liquid nitrogen tank brings great difficulties. At this time, a small electric vacuum cleaner can be used to suck out the fog. The specific operation method is as follows: the suction port of the vacuum cleaner is facing the fog, and the dust collector is turned on, and the fog is removed,

As shown in Figure 3. The one button defrosting function on the instrument can also be used, but this function will increase the liquid nitrogen consumption.

    

Fig. 3 Schematic diagram of fog removal

3. Washing and drying of gas phase liquid nitrogen tank After a long-term use of the gas-phase liquid nitrogen tank, the moist gas inside gradually accumulates into ice particles and adheres to the wall of the container. In addition, the straws and debris falling to the bottom of the container will gradually increase, which will adversely affect the stored biological products. Therefore, it is necessary to wash the container and remove the impurities. The washing cycle of the gas-phase liquid nitrogen tank is generally 1-2 The washing cycle can be determined by users. Before washing, the pipette or ammonia bottle stored in the container should be transferred to other containers, and the liquid nitrogen should be drained out, and the tank should be restored to normal temperature. When washing, the container can be placed horizontally, and the tray and bottom of the container can be cleaned with detergent solution. After cleaning, the residual water can be wiped with towel. Then, the hot gas (the temperature is not higher than 50 ℃) is blown into the container from the liquid inlet port of liquid nitrogen for drying.

4. Hardware equipment connection and operation

The pressure of liquid nitrogen should not exceed 1.2 MPa at the back of the liquid nitrogen container or the other end of the liquid nitrogen pressure vessel.

2) connect the power line, and the instrument is equipped with special aviation connector for power input and control input and output. The power cord of users shall be no less than 2.5mm square copper core wire. 2.5mm square copper core wire shall be selected for grounding protection wire, which shall be reliably connected with the ground. If the user does not set the protective grounding wire
(only the contact protector can realize leakage protection), the user must set the protective grounding device specially for the equipment to connect with the shell according to the power system specification requirements. In lightning prone areas, lightning protection measures must be taken. In this way, it can prevent thunder and lightning from causing damage to microcomputer components
The destruction.

Attention: please connect the machine with the earth reliably to prevent electric shock!

3) commissioning

For the first time (or not used for a long time), turn on the power supply of the control system, enter the system setting menu, manually open the solenoid valve in the equipment test column, and blow out the impurities in the system pipeline with dry nitrogen (about 3 minutes), so as to avoid blocking the solenoid valve and affecting the normal operation. Repeat several times
The effect is the best.

Attention: after the test of manual opening solenoid valve, remember to close it manually.

4) according to the required temperature of frozen products, the operation time of frozen products is determined, the tank cover is closed, the power is turned on, the operation mode is selected, the equipment starts to work, the control system enters the monitoring state, and the system displays the temperature change in the liquid nitrogen tank in real time.

Vi. precautions for safe operation and common faults

In case of high vacuum, avoid collision.

2. When filling liquid nitrogen for the first time, a small amount of liquid nitrogen (about 100L) should be filled for precooling, and then the liquid nitrogen should be filled after approaching the heat balance (the gasification is not violent).

3. Skin contact with liquid nitrogen will cause frostbite. The following points should be paid attention to during operation: (1) epithelial gloves must be worn and hands and feet should not be exposed;

(2) do not wear long shoes to avoid liquid nitrogen falling into the shoes;

(3) when the handle is rotated, it is better not to touch the other parts of the handle;

(4) filling liquid nitrogen should be carried out in a well ventilated place. If it is carried out indoors, the doors and windows should be opened to avoid asphyxia caused by lack of oxygen.

4. The vacuum sealing plug of the container is a live connection. When the container is damaged accidentally, liquid nitrogen enters the interlayer space and vaporizes and pressurizes rapidly, the sealing plug will be opened to form a pressure relief port to discharge nitrogen, which can play the role of bursting disc and ensure the safety and reliability of the product. Do not remove
The company will not be responsible for any loss caused by any man-made opening and operation marks found at the interface during any operation of vacuum sealing mask and vacuum sealing joint.

5. During transportation, the container should be placed at the position close to the front carriage plate and firmly fixed with heavy rope. It is not allowed to collide and scratch the container. It is strictly forbidden to get off the vehicle when it is full of liquid nitrogen and frozen articles.

6. Four high-strength casters are installed at the bottom of the container, which can be easily moved in a short distance indoors with liquid nitrogen and frozen articles inside. When moving indoors, care should be taken not to push and move violently to prevent collision. It is forbidden to move on the uneven ground outside.

7. Welding on product surface is not allowed.




Bande liquid nitrogen tank series products provide one year free after-sales service
Five year vacuum warranty.
Tel: 010-80204245
Mobile phone: 15611258074
Q Q: 2678388834
Email: 2678388834@qq.com
Address: Anshun South Road, Huangcun, Daxing District, Beijing
shrink
  • Telephone consultation

  • 010-80204245
  • Wechat consulting